No Injector Buzz, No DTC's, No Start
#1
No Injector Buzz, No DTC's, No Start
I know there are a million No Start threads - feels like I have read them all. But still no help for me.
I had a rebuilt motor installed after a rod went thru the block. Everything great for ~1000 miles of light use. Then one day - no start. After 3 attempts, I could finally hear injector buzz at key-on, then it fired. For a week or two - same thing - had to turn key on/off a couple of times to hear buzz, then it would fire. Fired & started one time last weekend, then dead again. Now - no buzz, no start.
FICM is Swamps 58V, about 3 years old. All Injectors are new. I'm using ForScan w/generic reader. 160 rpm cranking, FICM SYNC OK, IPR 15% cranking, ICPDES 1025psi, ICP 1.63V. All FICM-Voltage PID's in spec.
Only codes related to EGR delete & P1000. Checked all grounds & voltage at FICM X3 connector - all good. FICM Voltage read directly 58V IGN ON, drops to 55V cranking.
Checked Injector harness - seems OK, all injector coils measure in spec for resistance at FICM Connectors X1 & X2.
Also tried running injector buzz test in Forscan Tool - test aborts due to "conditions for test not met"
Any suggestions at all? For some reasons, injectors are not firing with some intermittent problem. If they fire, it starts. Because I don't get the buzz at Key On, I know this can only be an electrical issue.
Thanks!
I had a rebuilt motor installed after a rod went thru the block. Everything great for ~1000 miles of light use. Then one day - no start. After 3 attempts, I could finally hear injector buzz at key-on, then it fired. For a week or two - same thing - had to turn key on/off a couple of times to hear buzz, then it would fire. Fired & started one time last weekend, then dead again. Now - no buzz, no start.
FICM is Swamps 58V, about 3 years old. All Injectors are new. I'm using ForScan w/generic reader. 160 rpm cranking, FICM SYNC OK, IPR 15% cranking, ICPDES 1025psi, ICP 1.63V. All FICM-Voltage PID's in spec.
Only codes related to EGR delete & P1000. Checked all grounds & voltage at FICM X3 connector - all good. FICM Voltage read directly 58V IGN ON, drops to 55V cranking.
Checked Injector harness - seems OK, all injector coils measure in spec for resistance at FICM Connectors X1 & X2.
Also tried running injector buzz test in Forscan Tool - test aborts due to "conditions for test not met"
Any suggestions at all? For some reasons, injectors are not firing with some intermittent problem. If they fire, it starts. Because I don't get the buzz at Key On, I know this can only be an electrical issue.
Thanks!
Thread
Thread Starter
Forum
Replies
Last Post
Cavnar
Diesel In Distress - Support Ticket
3
09-09-2015 07:18 PM
cjgregory
Diesel In Distress - Support Ticket
0
03-31-2015 01:45 PM
ronstop
5.9 Liter CR Dodge Cummins 03-07
0
02-26-2015 09:48 AM
carid
Diesel Bombers Sponsors
0
11-18-2014 06:49 AM