5.9L Rotary Performance Discussion of 12 Valve 5.9 Liter Dodge Cummins Diesels with Rotary Injection Pumps Related To Performance And Longevity

run away question

Thread Tools
 
Search this Thread
 
  #1  
Old 11-02-2009 | 06:12 PM
cumminskid92's Avatar
Thread Starter
|
Diesel Enthusiast
Joined: Dec 2008
Posts: 305
Likes: 4
Default run away question

why cant you just flip the manual shut off when you have a run away. i made my truck run away to see if it would work and it killed it right away. of course my buddy had my psychology book ready to choke it out if it didnt.
 
  #2  
Old 11-02-2009 | 07:38 PM
muskrat's Avatar
Diesel Wrench
Joined: May 2009
Posts: 538
Likes: 39
From: Bitterroot Valley Mt
Default

It'll work, but unreliably. Generaly if the engine is running under 3800 rpms it may work, because it does the same thing the governor does. It's not a recomended to rely on that, ALWAYS be ready to cut off the air supply. Ive also heard of a guy using a phone book to choke the air off and pages got sucked into the turbo. So, yes it may work, but if you're engine is really running away, it might not. Cutting off the air is the only sure way to kill the engine.
 
  #3  
Old 11-02-2009 | 07:41 PM
Whit's Avatar
Site Mascot
Joined: Mar 2007
Posts: 16,010
Likes: 940
From: Why-homing
Default

a big coat works well on the intake too.........dont get yer hand by the thing it will pull it off
 
  #4  
Old 11-28-2009 | 04:17 PM
DirtyDozen's Avatar
Diesel Fan
Joined: Jul 2009
Posts: 75
Likes: 7
From: Prince George, B.C.
Default

best shut down device i ever seen or heard about is the Halon fire extinguisher, a quick shot out of one of these into the turbo and that thing quits instantly!

theyre not good for the environtment or some crap like that, and if you get any in your mouth it'll drown ya, so theyre getting kind of hard to come by depending on where you are, i know here in BC they've essentially outlawed them in any industrial/workplace setting, and no one will service them, but they can still be found, the fire extinguisher guys(sales/service) always seem to have a couple around, just gotta ask

(and its freakin hilarious if youve got one handy for the first fire up of a fresh rebuild, you hafta see the look on a guys face 5 seconds after it flashes up, hes chewing his fingernails off watching guages like a hawk and that brand new engine goes SQUEAK! and quits!!)
 
  #5  
Old 11-28-2009 | 04:29 PM
RSWORDS's Avatar
BOMBARDIER

Joined: Mar 2007
Posts: 11,159
Likes: 918
From: Gloucester, VA
Default

For a true runaway the manual shut off will not work. The only way to stop a true runaway is to cut the air supply.
 
  #6  
Old 11-29-2009 | 06:38 PM
seandonato73's Avatar
Diesel Wrench
Joined: Oct 2009
Posts: 603
Likes: 9
From: lebanon, Pa
Default

x2 thats how we do it at work if we encounter a runaway, two pieces of 1/2" thick x12"x12" plywood(we work on industrial diesels, most have a turbo on both banks of the engine)
 
  #7  
Old 11-29-2009 | 06:53 PM
diesel pap's Avatar
Site Sponsor - Mighty Diesel
Joined: Dec 2008
Posts: 4,184
Likes: 213
From: West Virginia
Default

have you guys ever saw a run away from natural gas. back hoes working on pipeline leaks and get a shot thru intake.
 
  #8  
Old 11-29-2009 | 11:10 PM
tower_ofpower's Avatar
Diesel Bomber
Joined: Jul 2009
Posts: 1,861
Likes: 86
From: Kingwood, WV
Default

Originally Posted by diesel pap
have you guys ever saw a run away from natural gas. back hoes working on pipeline leaks and get a shot thru intake.
i've heard of it... my dad talks about it with dozers when they rip thru a gas line... only thing you can pretty much do is just go for one hell of a ride. mechanical engines are nice but electronics also make run aways much harder to come by.
 
  #9  
Old 11-29-2009 | 11:28 PM
big bad diesel 416's Avatar
Site Sponsor
Joined: Apr 2009
Posts: 3,719
Likes: 636
From: Lexington SC
Default

and even then i saw a rig with a shitty Intercooler patch that failed while running away and they covered the turbo and nothing needless to say it is best to take loose the intake horn and covet there with a 2x6 with a little mudflap glued to it and if your working on a 2 stroke Detroit and is runnin away backwards remember to cover the exaust NOT THE INTAKE
 
  #10  
Old 11-30-2009 | 04:17 PM
stillcummin's Avatar
Diesel Enthusiast
Joined: Apr 2009
Posts: 255
Likes: 2
From: Chardon,Oh(cleveland
Default

runaway backwards?like exhaust out the intake?
 


Quick Reply: run away question



All times are GMT -5. The time now is 09:23 PM.