#6
First: I am not sure if you are serious or just joking but if you truly are serious then I would like to politely correct you and let you know there is a rack plug located on the very front of the P7100.
Second: More fuel
1. Crank star wheel all the way up
2. Remove fuel plate
3. Install 2095 rack plug
4. Install adjustable fuel pressure screw
5. Rack barrels
6. Install delivery valves
7. Advance injection timing
That's all that I have done to mine and without spending big bucks on new plungers, barrels, and lines I
believe this is just about all you can do. I don't believe adjusting the AFC supplies necessarily more fuel I think it just changes the curve of fuel flow based on your RPM's. Please correct me if someone knows otherwise.
Second: More fuel
1. Crank star wheel all the way up
2. Remove fuel plate
3. Install 2095 rack plug
4. Install adjustable fuel pressure screw
5. Rack barrels
6. Install delivery valves
7. Advance injection timing
That's all that I have done to mine and without spending big bucks on new plungers, barrels, and lines I
believe this is just about all you can do. I don't believe adjusting the AFC supplies necessarily more fuel I think it just changes the curve of fuel flow based on your RPM's. Please correct me if someone knows otherwise.